Vapor Pressure Tester

1. Floor type structure. Stainless steel working table. It is good looking and easy to operate. Accessories are complete. 2. Digital temperature controller. The temperature in water bath is uniform. Temperature control accuracy is high. It can meet the requirements of test. 3. Two precise pressure meters to detect the gas pressure inside the bomb.…

Rotational Viscometer

1. Measurement range: 10 mPa·s~2000000 mPa·s 2. Spindle: No.1~No.4, four spindles 3. Rotation speed: 0.3 RPM, 0.6 RPM, 1.5 RPM, 3 RPM,6 RPM, 12 RPM, 30 RPM, and 60 RPM; 8 grades in total 4. Measuring accuracy: ±1% (F·S) 5. Power supply: AC 220 V±10%, 50 Hz±10%; 6. Ambient temperature: 5 ºC~35 ºC; 7. Relative humidity: ≤80%; III. Optional parts 1. HWY-10 Circulation water bath 2. Double-layer sample cup…

Gas Chromatography

Temperature Control : Temperature Range:7℃ ~ 400℃ above room temperature, (increment 1℃) Temperature Control Object:Column Box, front and back detector, front and back sampler, assist,total six channels. Program ramps : 7 ramps in total Program setting:0.1℃~40℃/min(increment 0.1℃) Total time of total program : Up to 655 minutes, (increment 0.1℃) Hydrogen flame ionization detector (FID): Minimum detectable quantity: M≤8×10-12g/s (C16) Best test result: M≤3×10-12g/s (C16) Noise: ≤5×10-14A Drift: ≤6×10-13A/h Linearity range: ≥106 Thermal conductivity detector(TCD): Sensitivity:≥5000mV.mL/mg (C16) Noise: ≤20µVDrif: ≤30µV/hLinearity rang: ≥104 High Sensitivity Thermal conductivity detector(HTCD): Sensitivity: ≥10000mV.mL/mg (C16) Electron capture detector(ECD): Detectability: ≤1×10-13g/s  (γ-666) Linearity range: ≥103 Maximum using temperature:  350℃ Flame photometric detector(FPD): Nitrogen-phosphorus detector(NPD):Detectability: ≤2×10-11g/s(P)  (Parathion-methyl)≤1×10-10g/s(S)  (Parathion-methyl) Detectability: ≤5×10-12g/s(N)  (Azobenzene)≤5×10-13g/s(P)  (Malathion) (On programmed) Photoelectric ion detector(PID): Detectability: ≤1ppb (Benzene) – Include Nitrogen Hydrogen and Air Generator  

Distillation Tester

1. Power supply:   AC(220±10%)V, 50Hz 2. Heating power:   1000W,continuous adjustment 3. Receiving cylinder:  100ml,scale division 1ml 4. Distillation flask:  125mL. It can meet requirements GB/T 6536 and ASTM D86 5. Thermometer:   (-2~300)ºC and (-2~400)ºC. Division value 1ºC 6. Flask support board:  SiC,diameter for each hole is φ32mm,φ38mm and φ50mm 7. Ambient temperature:   Room temp.~+35ºC 8. Relative humidity:   ≤85% 9. Maximum power consumption:  1100W 10.Dimension:   460mm×400mm×500mm

Dean Stark Distillation Apparatus

1. ASTM D95 dean stark apparatus is designed totally meeting the requirements of GB/T260. 2. The gripper is designed reasonably. The installation and dismantlement are convenient. 3. The heating power is continuously adjustable. The voltmeter displays the power intuitionally. The temperature control is reasonable. 4. ASTM D95 dean stark distillation tester can do parallel test for two samples.The working…

Automatic Pour Point Tester

Executive standard  GB/T3535,GB/T510; Measuring range: Room temperature ~ -45℃; Precision: ± 0.1℃; Display: Digital tube display; Test method: automatic temperature control, manual testing; Temperature probe: PT100 platinum resistor ; Testing hole: two holes; Refrigerating rate: ≥ 70℃/h Refrigerating method: compressor refrigeration; Power: 1500W  ; Power voltage: AC 220V 50Hz; Applicable environment: temperature ≤ 40℃, humidity…

Engler Viscometer WNE-1A Biobase

Engler Viscometer Digunakan untuk mengukur viskositas (kekentalan) pada fluida (dibandingkan dengan kecepatan aliran air) Spesifikasi: Power supply: AC 220V ±10%, 50Hz Standar water value: 51±1s Temperature range: 0~100°C Temperature controlling accuracy: ±0.1°C Engler viscometer thermometer: as per GB/T514 Graduated flask: 200±0.2 ml (50±0.2 ml for bituminous materials) Inner container: Made by stainless steel Timer: is…