Technical Data :
Life of gyrosphere: more than 10000h
Mean time between failures: more than 2000 h
Settle point error: not exceed +0.75° x Secφ
Repeatability error of settle point headings: not exceed 0.25° x secφ Heading error in straight and uniform sailing: not exceed +1° x secφ
Error due to rapid alteration of speed of 20knots: not exceed +1.5° Error due to rapid alteration of course of 180° at speed of 20 knots: not exceed +2.5°
Rapid setting time: less than 2h Adaptable ship’s power supplies: AC 220V 50Hz
The max difference of readings between the master compass and repeater: +0.5°
Transmission: Torque transmitter, 50Hz
Main technical performance indicators
Stable point error: within ±0.5×Secφ
Repeatability error of stability point error: ≤ 0.25 × Secφ
Stabilization time: ≤ 4h
Swing error: within ±1°×Secφ
Physical parameterMean time between failures: ≥3000h
CLP-2H main compass dimensions: (L)314mm × (W)401mm × (H)405mm
CLP-2H main compass installation method: floor type
CLP-2H main compass weight: 30KG
Power box dimensions: (L)320mm × (W)130mm × (H)370mm
Power box installation size: 290mm × 300mm
Power box installation method: wall-mounted
Power box weight: 12KG
Heading send box Dimensions: (L)465mm × (W)320mm × (H)120mm
Heading send box installation size: 360mm × 290mm
Heading send box installation method: wall-mounted